INES type: power-reactor

Legenda & explanation
date INES title location
1993-12-21INES 0REACTOR TRIP DUE TO MAIN CONDENSER VACUUM LOW SIGNALSouth KoreaKORI-2
1994-01-27INES 0MANUAL REACTOR SHUTDOWN CAUSED BY THE FAILURE OF THE MANUAL REACTOR CONTROL ROD SYSTEMLithuaniaIGNALINA-2
1994-02-03INES 0TURBINE TRIP AND REACTOR POWER DECREASE DUE TO FAILURE OF AUXILIARY TRANSFORMER AT NPP DUKOVANYCzech RepublicDUKOVANY-3
1994-02-22INES 0LEAKAGE OF FEEDWATER THROUGH WELDED JOINT OF A NB 76 PIPELINE CONNECTING ECCS HEADER WITH DISTRIBUTION GROUP HEADERRussian FederationLENINGRAD-1
1994-03-08INES 0SHUNT TRANSFORMER INFLAMMATION AT THE HIGH-VOLTAGE (750 KW) LINE SWITCHYARDUkraineZAPOROZHE-1
1994-01-11INES 0REACTOR TRIP DUE TO FAST CLOSURE OF MAIN STEAM ISOLATION VALVE (MSIV)South KoreaKORI-4
1993-03-30INES 0TURBINE TRIP ON SG HIGH-HIGH WATER LEVEL FOLLOWED BY REACTOR TRIPChinaQINSHAN 1
1994-07-09INES 0RELEASE OF IODINE 131 FROM THE TURBINE SYSTEM AT RINGHALS 1SwedenRINGHALS-1
1994-07-08INES 0AUTOMATIC REACTOR SHUTDOWN CAUSED BY SPURIOUS CLOSING OF THE GATE VALVE AT THE PIPELINE FEEDING THE MAIN CONDENSATE HEATER WITH HEATING STEAMLithuaniaIGNALINA-2
1994-05-23INES 0REACTOR TRIP DUE TO FAILURE OF MAIN FEEDWATER CONTROL VALVE (MFCV)South KoreaULCHIN-2
1994-06-29INES 0REACTOR TRIP DUE TO GROUND OF MAIN GENERATOR PROTECTION RELAYSouth KoreaKORI 1
1994-07-14INES 0AUTOMATIC SHUT DOWN OF THE REACTOR AFTER GENERATOR PROTECTION ACTIVATIONSloveniaKRSKO
1994-08-11INES 0SLIGHT CONTAMINATION AT THE NUCLAR ELECTRICITY PRODUCTION CENTRE OF DAMPIERREFranceDAMPIERRE-1
1994-06-16INES 0FLOODING IN BASEMENT AND SUB BASEMENT OF TURBINE BUILDINGIndiaKAKRAPAR-1
1994-08-21INES 0REACTOR SHUTDOWN CAUSED BY LEAKAGE THROUGH A JOINT WELD IN THE ECCS PIPEWORKLithuaniaIGNALINA-1
1994-02-02INES 0REACOR SCRAM AND TURBINE TRIP BY RCP BUS LOW VOLTAGEChinaQINSHAN 1
1994-05-25INES 0REACTOR SCRAM BY ATWT SIGNAL DURING PERIODIC TESTChinaGUANGDONG-1
1994-08-22INES 0ONE CONTROL ROD NOT FULLY INSERTED AFTER SCRAMSwedenRINGHALS-4
1994-08-09INES 0AUTOMATIC REACTOR SHUTDOWN CAUSED BY GENERATOR TRIPLithuaniaIGNALINA-1
1994-09-25INES 0REACTOR TRIP DUE TO TURBINE TRIP CAUSED BY STEAM GENERATOR LEVEL "HI-HI" SIGNALSouth KoreaKORI-2
1994-11-03INES 0INFRINGEMENT OF THE REACTOR PRIMARY CIRCUIT INTEGRITYLithuaniaIGNALINA-1
1994-03-06INES 0DEPRESSURIZATION OF CONTROL ROD HOUSING DISCOVERED DURING ROUTINE INSPECTIONRussian FederationKOLA-3
1994-12-04INES 0LEAKAGE IN MANUAL VALVE INTO TECHNICAL SPECIFICATIONSSpainALMARAZ-1
1994-12-03INES 0TURBINE AND REACTOR TRIP DUE TOMFCV TROUBLESouth KoreaYONGGWANG-1
1995-02-23INES 0SMALL LEAKAGE OF PRIMARY COOLANT AT NPP BIBLIS, UNIT BGermanyBIBLIS-B