date | INES | title | location |
18-09-1990 | INES 2 | SPURIOUS ACTUATION OF 2 MAIN SAFETY VALVES OUT OF TWELVE | IGNALINA-1, Lithuania |
01-06-1991 | INES 1 | UNIT SHUTDOWN DUE TO PERSONNEL ERRORS AND DAMAGE TO RCP 6 KV BREAKER | KALININ-2, Russian Federation |
11-05-1991 | INES 1 | UNPLANNED EXPOSURE OF PERSONNEL DURING REFUELLING | KOZLODUY-5, Bulgaria |
26-02-1991 | INES 3 | INOPERABILITY OF VALVES AT THE DISCHARGE SIDE OF HPSI PUMPS IN THREE TRAINS DUE TO FAILURE TO CONNECT POWER CABLES | KHMELNITSKI-1, Ukraine |
31-03-1991 | INES 1 | WRONG POSITIONING OF THE FUEL ASSEMBLY WHILE PERFORMING FUEL ROD CLADDING INTEGRITY TEST | KOLA-2, Russian Federation |
28-03-1991 | INES 0 | UNIT SHUTDOWN DUE TO SHORT CIRCUIT IN THE AUXILIARY POWER TRANSFORMER AND LEAKING OIL FIRE | LENINGRAD-3, Russian Federation |
27-03-1991 | INES 0 | UNIT SHUTDOWN DUE TO PRIMARY CIRCUIT LEAK IN THE LINE OF CONTROLLED LEAKS FROM THE MAIN ISOLATION VALVE SEAL | SOUTH UKRAINE-1, Ukraine |
13-02-1991 | INES 0 | REACTOR SHUTDOWN DUE TO EXCESS HYDROGEN CONCENTRATION IN THE GENERATOR STATOR GAS TRAP | ZAPOROZHE-4, Ukraine |
11-01-1991 | INES 1 | UNIT SHUTDOWN DUE TO SG-4 PULSE LINE RUPTURE | NOVOVORONEZH-5, Russian Federation |
06-12-1990 | INES 1 | TURBINE SJAES STEAMING DUE TO PLANT PERSONNEL ERROR | SMOLENSK-3, Russian Federation |
12-04-1991 | INES 2 | FIRE IN SWITCHGEAR BUILDING | OLKILUOTO-2, Finland |
21-02-1991 | INES 0 | UNIT SHUTDOWN DUE TO COOLANT LEAK IN RCP AUXILIARY PIPELINE | KURSK-4, Russian Federation |
05-02-1991 | INES 1 | PRESSURIZER DISCHARGE TANK MEMBRANE RUPTURE | KOZLODUY-2, Bulgaria |
15-01-1991 | INES 2 | FIRE OF BUSES OF SECOND CATEGORY OF RELIABILITY BUSES | BOHUNICE-2, Slovakia |
21-01-1991 | INES 0 | REACTOR SCRAM DUE TO A FIRE OF SECOND CATEGORY OF RELIABILITY BUSES | DUKOVANY-1, Czech Republic |
20-11-1987 | INES 2 | CRITICALITY SHUT DOWN MARGIN MEASUREMENT STARTED WITHOUT HYDRAULIC SCRAM SYSTEM BEING OPERABLE | OSKARSHAMN-3, Sweden |
21-12-1990 | INES 1 | REACTOR COOLANT LEAKAGE DUE TO FAILURE OF SEALING OF MAIN REACTOR FLANGE | KOZLODUY-2, Bulgaria |
04-12-1990 | INES 2 | LOSS OF ELECTRICAL OFF-SITE POWER AFFECTED THE FOUR UNITS LOAD REJECTION AND DIESEL GENERATOR FAILED | DUKOVANY-1, Czech Republic |
01-10-1990 | INES 1 | FAULTY WELD DETECTED ON PRIMARY CIRCUIT | OSKARSHAMN-1, Sweden |
01-10-1990 | INES 2 | IMPACT ON SAFETY DUE TO PARTIAL INOPERABILITY OF THE LONG TERM COOLING SYSTEM (WATER SUMP FILTERS) | PALUEL-1, France |
22-08-1990 | INES 2 | IMPACT ON SAFETY DUE TO INOPERABILITY OF A SAFETY SYSTEM DESIGNED FOR ACCIDENT MITIGATION (CONTAINMENT SAND FILTERS) | TRICASTIN-1, France |
01-07-1990 | INES 2 | IMPACT ON SAFETY DUE TO VIOLATION OF OPERATIONAL LIMITS AND CONDITIONS (IMPURITY DUE TO AIR INGRESS) | CREYS-MALVILLE, France |
22-07-1990 | INES 1 | LOSS OF POWER SUPPY TO REACTOR COOLANT PUMPS DUE TO 6 KV CABLE FIRE | SMOLENSK-2, Russian Federation |
05-07-1990 | INES 2 | INOPERABILITY OF NEUTRON FLUX MEASUREMENT DURING COLD SHUTDOWN | GREIFSWALD-5, Germany |
30-07-1990 | INES 0 | LEAKAGE IN THE UNDERGROUND TUBE OF THE INTERMEDIATE COOLING CIRCUIT | KRUEMMEL, Germany |
30-06-1988 | INES 1 | DEGRADATION OF NATURAL CIRCULATION | PAKS-4, Hungary |
20-08-1974 | INES 2 | EXCESSIVE DEPRESSURIZATION OF THE PRIMARY CIRCUIT DUE TO A PRESSURIZER SAFETY VALVE THAT FAILED TO CLOSE | BEZNAU-1, Switzerland |
05-01-1990 | INES 0 | AUTOMATIC PLANT SHUTDOWN DUE TO AN EARTHQUAKE | KRSKO, Slovenia |
07-07-1990 | INES 1 | REACTOR COOLANT LEAK ON REACTOR TEMPERATURE DETECTOR | VANDELLOS-2, Spain |
23-02-1990 | INES 2 | REACTOR COOLANT LEAK ON THE WATER CLEANING SYSTEM WHILE CONNECTED TO THE PRIMARY CIRCUIT | Greifswald, Germany |