INES-event
INES 2

FAILURE OF SAFETY SYSTEM TRAIN WHILE ROUTINE TESTING

The unit was operating at nominal power. During the routine test of the 3QW diesel generator (DG) the failure of this DG control system occurred. The DG was taken out of service for maintenance. 5 hours 41 minutes after the event the 3QW DG was tested under load and placed in expectation mode. While taking the affected DG out of service for repair personnel failed to test the two remaining safety system (SS) trains, which constitutes a breach of technological procedure requirements. Thus, a breach of safe operation conditions occurred. The testing of SS trains 1 and 2 was performed successfully according to the schedule.
BASIS FOR RATING: Initial event -failure of one SS train. Event - expected, postulated. Safety function availability - sufficient, which correponds to level 1/2 (C-1P). The event reveals safety culture deficiencies (item 4.2 b), therefore level 2 has been chosen.
DIFFICULTIES IN RATING:

Location: KOLA-3
Event date: Thu, 16-05-1991
Nuclear event report