date | INES | title | location |
16-07-1991 | INES 0 | UNIT NO. 1 REACTOR SCRAM ON PRM HIGH FLUX | TARAPUR-1, India |
19-06-1992 | INES 0 | UNIT NO. 1 SCRAM ON PRM CH. 6 & IRM CH. 9 KICKING UP DURING FUNCTIONAL CHECKS | TARAPUR-1, India |
15-06-1992 | INES 0 | REACTOR UNIT NO. 1 SCRAM ON TOTAL LOSS OF POWER | TARAPUR-1, India |
21-08-1992 | INES 1 | SOIL CONTAMINATION WHILE PUMPING OUT RAIN WATER FROM TAPS-TRAP TRANSFER LINE INSPECTION PIT | TARAPUR-1, India |
16-10-1992 | INES 0 | REACTOR SCRAM ON PRM HIGH FLUX | TARAPUR-1, India |
10-11-1995 | INES 1 | Non-closure of primary steam isolating valves on auto during total loss of power incident | TARAPUR-1, India |
08-05-1995 | INES 1 | INADVERTENT DISCHARGE OF LIQUID RADIOACTIVE WASTE | TARAPUR WASTE IMM. PLANT, India |
02-03-2000 | INES 1 | Loss of a Promethium source (18.5 GBq) | TANDEM CONSULTANTS, France |
06-04-2012 | INES 2 | Overexposure to Radiographer’s Assistant | Tampa, Florida/Renegade Testing & Inspection, INC., United States of America |
27-01-2016 | INES 2 | Worker Overexposure | Tampa, Florida / Cardinal Health, United States of America |
08-10-2014 | INES 1 | THEFT OF RADIOACTIVE SOURCES | Talara, Piura, Geowell S.A.I.C., Peru |
21-06-2019 | INES 2 | Hand contamination of radiation workers | Sydney, ANM Facility, ANSTO Lucas Heights, Australia |
02-01-2002 | INES 3 | High radiation levels measured on a package containing Iridium-192 | Studsvik Nuclear AB, Sweden |
13-08-1996 | INES 1 | Water leak into a hot cell at the Studsvik research establishment | Studsvik Nuclear AB, Sweden |
20-09-2004 | INES 0 | Event at a Studsvik laboratory producing radioactive sources | Studsvik Nuclear AB, Sweden |
21-09-2017 | INES 2 | Contamination event at research facility | Studsvik Nuclear AB, Sweden |
19-09-2012 | INES 2 | Overexposure of a radiographer | Stork Technical Service, Belgium |
11-03-2006 | INES 4 | Overexposure of employee in irradiation facility | STERIGENICS - Fleurus, Belgium |
07-05-2009 | INES 2 | Incident at Irradiation Facility | STERIGENICS - Fleurus, Belgium |
16-11-2014 | INES 2 | Realizing of maintenance activities without respecting the procedures | Sterigenics, Belgium |
09-07-2004 | INES 2 | Potential Overexposure to Members of the Public | State of Texas, United States of America |
14-08-1991 | INES 0 | INTERNAL LEAKAGE OF PRESSURIZER SAFETY VALVES | STADE, Germany |
11-10-1992 | INES 2 | METALLURGICAL DEFECTS ON THE MAIN STEAM LINES OF A REACTOR | ST. ALBAN-1, France |
02-03-2015 | INES 2 | Transport incident of a gamma ray projector | St Pol-sur-Mer (59) and Courcelles-les-Lens (62), France |
02-05-2014 | INES 1 | Inspection of Container No.TSAU 2600500 for Radioactive Contamination | sri lanka colombo port, Sri Lanka |
28-05-1993 | [N/A] | EXTRAORDINARY SHUTDOWN OF THE UNIT BECAUSE OF HYDROGEN LEAKAGE IN THE COOLING SYSTEM OF THE GENERATOR | SOUTH UKRAINE-3, Ukraine |
12-11-1992 | INES 1 | UNIT OPERATION WITH ONE REACTOR PROTECTION SYSTEM CHANNEL OUT | SOUTH UKRAINE-2, Ukraine |
22-08-1997 | INES 2 | Fresh fuel assembly damage during refuelling | SOUTH UKRAINE-2, Ukraine |
27-03-1991 | INES 0 | UNIT SHUTDOWN DUE TO PRIMARY CIRCUIT LEAK IN THE LINE OF CONTROLLED LEAKS FROM THE MAIN ISOLATION VALVE SEAL | SOUTH UKRAINE-1, Ukraine |
01-12-1990 | INES 2 | ESSENTIAL BUS DEENERGIZATION | SOUTH UKRAINE-1, Ukraine |