INES 1

WATER INGRESS IN ION CHAMBER HOUSING OF CHANNEL B & E OF REACTOR REGULATING AND PROTECTIVE SYSTEM

During full power operation, channel B of Reactor Regulating System and channel E of Reactor Protective System were reading less neutron power than other channels. To match with other channels, gain of ion chamber amplifiers of these channels was increased and also manual correction on protective channel E was done. Linear neutron trip set-points from primary shutdown system and secondary shutdown system were decreased. No problem could be found in ion chambers and their associated circuitry. On further investigation during reactor shutdown water was found in ion chamber housing, which caused the low neutron power signal in channel B & E (channel B and Channel E, both ion chambers are in same housing).
Justification: Unplanned bulk increase in reactivity could have been the possible initiator. Since no initiator occurred, Table-1 has been used for rating. The safety function availability was full, so the event rating comes to 0. But due to possibility of common cause failure (water ingress into other ion chambers also) the event has been uprated by 1.

Location: NARORA-2
Event date: Sat, 27-02-1993