This is an isotope manufacturing facility. The licensee technician needed to transfer a Co-60 source drawer into a shielded container called a therapy head. A special handling tool had been bolted to the end of the source drawer and this tool was needed to safely transfer the source back inside the therapy head. The technician attempted to move the source drawer in order to gain access to the handling tool but the source drawer was stuck, so the technician pulled on the drawer. In doing so, the drawer slid out of the cask about 22.8 cm (9 inches), bringing the source to within an estimated 5.1 cm (2 inches) of the cask external surface and exposing the technician. The technician quickly pushed the source drawer back inside the cask and noted that the electronic personnel dosimeter (whole body) being worn by the individual was reading 56.2 mSv (5.62 rem). The technician was not wearing extremity dosimetry. The technician immediately left the area. The licensee’s preliminary calculations are a whole body dose of 169 mSv (16.9 rem). Depending on various assumptions, the extremity dose is estimated to be between 2,370 mSv and 9,500 mSv (237 to 950 rem). The technician’s badge has been sent for emergency processing and the individual is being restricted from radiation work for the time being. NRC EN51331
UPDATE: The NRC conducted a comprehensive follow up inspection for this event. The NRC and company officials found, through a review of the video surveillance, that the technician actually removed the source drawer from the cask and replaced it within 4-5 seconds. The source drawer contained approximately 135.6 TBq (3,664 curies) of Cobalt-60 and the design of the source drawer was such that the radiation beam was highly collimated. On October 1, 2015, the company informed the NRC that it was assigning a whole body deep dose equivalent of 56.2 mSv (5.62 rem) for the August 20, 2015 event, and a maximum extremity dose of 384 mSv (38.4 rem) to the technician’s left hand. The licensee determined that the root cause of the event was poor coordination and control and the technician’s removal of the source drawer. Corrective actions included personnel training and procedure modifications. NRC EN51331
Location: Idaho Falls, ID/ International Isotopes, Inc. Event date: Thu, 20-08-2015
Everywhere you look, the nuclear industry’s hype machine is in overdrive. Goldman Sachs, Microsoft, and the UK government all tout small modular reactors as the silver bullet for climate change and energy security. Tech billionaires are hiring nuclear veterans. Wall Street is whispering about “round-the-clock power” for artificial intelligence data centers. For those old enough […]
Kernenergie en veiligheid: A wargame sought to test if a major radiological release that would prompt the evacuation of millions of civilians in South Korea could distract key US allies from assisting and rebuffing an all-out military invasion of Taiwan. The short answer was yes. The game originally presumed that China, wanting to keep the […]
Big batteries and EVs to the rescue again as faults with new nuclear plant cause chaos on Nordic grids The Finnish nuclear power plant Olkiluoto was finally connected to the grid last year, at an estimated cost of €11 billion compared to the original budget of €3 billion. That cost blowout forced its developer, the […]
A vast subsea nuclear graveyard planned to hold Britain’s burgeoning piles of radioactive waste is set to become the biggest, longest-lasting and most expensive infrastructure project ever undertaken in the UK. The project [UK's nuclear waste dump] is now predicted to take more than 150yrs to complete with lifetime costs of £66bn in today’s money...The […]
Last year, the Dutch Province of Limburg started an alliance in which, besides the local government, research institutes, small nuclear reactor (SMR) developers, utilities, industrial customers and funders cooperated. With this "Limburg SMR alliance" Limburg tried to lead the way towards an SMR in Limburg. The preferred site for a first SMR would be Chemelot, […]