Publicatie Laka-bibliotheek:
An Investigation into the Falsification of Pellet Diameter Data in the MOX Demonstration Facility at the BNFL Sellafield Site and the Effect of this on the Safety of MOX Fuel in Use (2000)
| Auteur | Nuclear Installations Inspectorate |
| Datum | februari 2000 |
| Classificatie | 2.05.0.40/03 (GROOT-BRITTANNIË - PU / MOX / SMP (Sellafield Mox Plant)) |
| Voorkant | ![]() |
Uit de publicatie:
SUMMARY The MOX Demonstration Facility (MDF) at BNFL's Sellafield site manufactures MOX (mixed oxides of plutonium and uranium) fuel pellets and assembles these using various customer supplied components to make complete fuel assemblies for use in nuclear power reactors. Each fuel pellet produced passes through a fully automated laser micrometer which checks and records the pellet's diameter at three points along its length, giving a 100% automatic check on all pellets used in a fuel rod. Any undersized or oversized pellets are automatically rejected. Those which fall within the specified diametral tolerance pass onto the next stage where each undergoes further visual checks. As a confirmatory check on diameter and in accordance with the 1% Acceptable Quality Level (AQL) criterion set out in BS 6001, a sample of 200 pellets (approximately 5%) which have passed through both these stages is measured for a second time. This quality check is done using a similar micrometer, but the sample pellets are presented to the micrometer by process workers who type each measured diameter, e.g. 8.195mm, into a computer spreadsheet. On 20 August 1999 a member of MDF's Quality Control Team identified similarities between the secondary pellet diameter data for successive Lots. After further investigations, on 10 September 1999 BNFL reported to NII that some of these secondary pellet diameter checks on the fuel manufactured for a Japanese customer appeared to have been falsified by copying some data between spreadsheets. The Health and Safety Executive's Nuclear Installations Inspectorate (NII) promptly launched an investigation to establish both the extent of the falsification and the causes of the event. NII concluded that data had indeed been falsified but that this would not affect the safety performance of the fuel, given the automated primary diameter check on 100% of the pellets used in each fuel rod.
Deze publicatie is alleen op papier bij Laka beschikbaar, niet als pdf.
Publicaties zijn te leen of informeer of we een kopie kunnen maken. Soms, als we tijd hebben, lukt dat tegen kostprijs van de kopieën.