Laka Foundation

Publication Laka-library:
The Chernobyl accident: updating of INSAG-1. INSAG-7 (1992)

AuthorINSAG
DateNovember 1992
Classification2.34.8.10/76 (CHERNOBYL ACCIDENT - CONSEQUENCES SURROUNDINGS - GENERAL)
Front

From the publication:

1. INTRODUCTION

IAEA Safety Series No. 75-INSAG-1 (INSAG-1) was prepared by the International 
Nuclear Safety Advisory Group (INSAG) at the request of the Director General of the 
IAEA, following the Post-Accident Review Meeting on the Chernobyl Accident held 
in Vienna over the period 25-29 August 1986. At that meeting, leading Soviet 
scientists and engineers presented the first published account of the accident at the 
fourth unit of the Chernobyl nuclear power station in the Ukrainian Republic of the 
Union of Soviet Socialist Republics on 26 April 1986, along with a discussion of the 
accident's causes. They delivered their account to a large number of experts from 
IAEA Member States and from international organizations. IAEA Safety Series No. 
75-INSAG-1 was based upon this evidence, on additional material presented by the 
Soviet experts during the meeting and on discussions in Working Group sessions 
among the Soviet experts, INSAG members and other experts who assisted them.
Prior to the Vienna meeting, there had been worldwide speculation about the causes 
of the Chernobyl accident. Analytical studies prompted by this speculation were 
undertaken at numerous locations on the basis of incomplete information on the 
design characteristics of RBMK reactors published in the open literature. The Soviet 
experts' explanation to the meeting of the fault sequence leading to the destruction 
of Chernobyl Unit 4 was drawn from an analytical model 'normalized' to sparse and 
inaccurate plant data that had been recorded during the tests carried out on the turbo 
generator which led to the accident.
The account given to the Vienna Conference stated that it was possible to explain the 
nature of the accident and the extent of the resulting structural damage in terms of 
an uncontrolled reactivity driven excursion. It was said that this excursion had been 
made possible by the signs and magnitudes of the void and power coefficients of 
reactivity characteristic of the state of the reactor at the time. These had been 
inadvertently set up by the operators in preparation for the tests and by the effect 
of pump coastdown which reduced coolant flow as the test progressed. The Soviet 
presentation of the detailed account was accompanied by statements of violations by 
operators of procedures and rules. In the absence of evidence it was not possible to 
examine the appropriateness of these procedures and rules, or the protection system, 
in relation to the reactor's design characteristics. The assertion was made that the 
accident arose through a low probability coincidence of a number of violations of 
rules and procedures by the operating staff and those responsible for authorizing the 
test.

This publication is only available at Laka on paper, not as pdf.
You can borrow the publication or request a copy. When we're available, this is possible for a small fee.